Stronger lining for sensitive sites. No styrene, no odor.
Non-VOC, styrene-free lining for higher heat, chemical exposure, and locations where odor and air quality matter — hospitals, schools, occupied buildings, and municipal systems.
-- What is Non-VOC lining?
A cleaner resin for tougher jobs.
VOC stands for volatile organic compounds — the chemistry behind the strong odor most people associate with traditional CIPP resins. Non-VOC, styrene-free resin systems eliminate that odor while delivering higher strength, higher temperature resistance, and better chemical resistance.
That makes them the right call for challenging conditions — hot or chemically aggressive effluent — and for sensitive locations like hospitals, schools, and assisted-living facilities, where air quality and odor complaints can’t be an afterthought.
Best for:
Hospitals, schools, assisted-living, occupied buildings.
Handles:
High heat and chemically aggressive effluent.
Chemistry:
Styrene-free, low-odor resin system.
Standards:
ASTM F1216 / NASSCO compliant.
Built for sensitive sites
Where odor and air quality can't be an afterthought.
Healthcare
Hospitals & clinics
Education
Schools & campuses
Senior Living
Assisted-living facilities
Food Service
Restaurants & kitchens
Occupied Buildings
Densely populated areas
Why specify Non-VOC
Styrene-Free, Low Odor
No styrene smell — fewer odor complaints near occupied, sensitive sites.
Heat & Chemical Resistant
Stands up to higher temperatures and chemically aggressive effluent.
Stronger End Product
Higher-strength resin means a more durable finished liner.
Less Diameter Loss
Added resin strength preserves more flow capacity in the host pipe.
How to choose
Standard resin vs. Non-VOC.
Both are structural and trenchless. The difference is where each one fits.
Odor during install
Standard
Noticeable styrene odor
Non-VOC
Styrene-free, low odor
Temperature tolerance
Standard
Standard range
Non-VOC
Higher heat resistance
Chemical resistance
Standard
Suitable for typical effluent
Non-VOC
Handles aggressive chemistry
Best-fit site
Standard
Standard collection systems
Non-VOC
Sensitive & occupied sites
Lining near a hospital, school, or occupied building?
Specify Non-VOC When
The site is sensitive
Hospitals, schools, assisted living, food service, or densely occupied areas where odor and air quality matter.
Conditions are aggressive
Higher effluent temperatures or elevated chemical presence that standard resins can't handle long-term.
Flow capacity is tight
You need a stronger liner with less diameter loss to preserve capacity.
How we install Non-VOC lining.
01
Inspect & Assess
Camera-inspect and assess conditions — heat, chemistry, site sensitivity.
02
Specify Resin
Match the right non-VOC, styrene-free resin to the application.
03
Install & Cure
Saturate, position, and cure the liner with minimal odor and disruption.
04
Verify & Document
Final camera pass confirms a fully cured, structural liner.
0
Styrene Content
0
Feet Of Excavation
24/7
Emergency Dispatch
50+
Year Design Life
Faq
Common questions
Expand for chemistry, applications, and documentation.
VOCs are volatile organic compounds — the source of the strong odor in traditional CIPP resins. Non-VOC, styrene-free systems remove that odor while delivering higher strength and better heat and chemical resistance.
When the site is sensitive to odor or air quality — hospitals, schools, assisted living, occupied buildings — or when effluent runs hot or chemically aggressive. We assess conditions and recommend the right system for the application.
Yes. Styrene-free resin systems dramatically reduce the odor associated with conventional CIPP, which is the primary source of public complaints near occupied and sensitive locations.
Installed to ASTM F1216 / F1743 standards using NASSCO-compliant methods. Pre- and post-installation camera documentation provided for your records and inspectors.




Recent Project
Odor-Free Lining at an Occupied Assisted-Living Facility
A Central Florida care facility needed failing laterals rehabilitated without disrupting residents. We specified a styrene-free, non-VOC resin — no odor complaints, no relocation, full camera documentation for the property’s records.
Zero
Odor Complaints
Zero
Residents Relocated
Got a sensitive site or tough conditions? Let's spec it right.
We assess your conditions and recommend the right non-VOC system — then install it with minimal odor and disruption.